No products in the cart.

Now There’s a better way to build

SUSPENDED CEILINGS

SUSPENDED CEILINGS

1.      METAL CEILINGS

1.1.            CASETTE METAL CEILING

1.1.a.      LAY – ON SYSTEM

Lay-on system is formed by allowing aluminium or galvanised steel panels rest on T15/24 or T15/24 channel grid system. The runners are visible and all panels are demountable manually without any special tool so that the system enables fast and easy access to the ceiling void.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD
Panel type0.5 ~ 0.7 mm aluminium or galvanised steel
Panel size300 mm x 300 mm
600 mm x 600 mm
600 mm x 1200 mm
Grid systemT15/24 exposed grid
PerforationFull perfore, 5 cm – 10 cm bordered, non-perforated
Ø0.7 mm. / Ø1.5 mm. / Ø1.8 mm. / Ø2.5 mm.
Acoustic feltLocal, soundtex, royalin, lantor acoustic and non-flammable felt options
Certi cationsTSE, CE

 

1.1.b.     LAY – IN SYSTEM SEMI CONCEALED

Lay-in system is formed by allowing aluminium or galvanised steel panels lean on T15/24 or T15/24 channel grid system. This system is also called as “semi-concealed” as runners are visible but there is a shadow effect. All panels are demountable manually without any special tool so that the system enables fast and easy access to the ceiling void.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD
Panel type0.5 ~ 0.7 mm aluminium or galvanised steel
Panel size300 mm x 300 mm
600 mm x 600 mm
600 mm x 1200 mm
Grid systemT15/24 exposed grid
PerforationFull perfore, 5 cm – 10 cm bordered, non-perforated
Ø0.7 mm. / Ø1.5 mm. / Ø1.8 mm. / Ø2.5 mm.
Acoustic feltLocal, soundtex, royalin, lantor acoustic and non-flammable felt options
Certi cationsTSE, CE

 

1.1.c.      CLIP – IN SYSTEM CONCEALED

Standard clip-in system consists of a concealed supporting structure where demountable tiles can be clipped into the triangular omega main runner. The grid system is not visible thus providing more aesthetical and plain view comparing to the standard visible grid system. All panels are singularly and independently demountable thus enabling easy and fast access above the ceiling.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

0.5 ~ 1.0 mm aluminium or galvanised steel

Panel size

Width from 300 mm and length up to 2400 mm. Width from 600 mm and length up to 1200 mm.

Grid system

Grid system

Perforation

Full perfore, 5 cm – 10 cm bordered, non-perforated, Ø0.7 mm. / Ø1.5 mm. / Ø1.8 mm. / Ø2.5 mm.

Acoustic felt

Local, soundtex, royalin, lantor acoustic and non-flammable felt options

Certi cations

TSE, CE

1.1.d.      HOOKON SYSTEM CONCEALED

Hook-on system is used for large spaces where there is a need for frequent access to the ceiling void. It is a concealed system, panels are fully demountable with the help of a hooked grid profile hanged to the aluminium or galvanised steel panels. This system enables the installation of larger panels with the size 300 mm to 1800 mm in length.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD
Panel type0.5 ~ 1.0 mm aluminium or galvanised steel
Panel sizeWidth from 300 mm and length up to 2400 mm. Width from 600 mm and length up to 1200 mm.
Grid systemConcealed grid
PerforationFull perfore, 5 cm – 10 cm bordered, non-perforated Ø0.7 mm. / Ø1.5 mm. / Ø1.8 mm. / Ø2.5 mm.
Acoustic feltLocal, soundtex, royalin, lantor acoustic and non-flammable felt options
Certi cationsTSE (EN 13964), CE

1.1.e.       BANDRASTER SYSTEMS

A modern and crea ve ceiling system where panels are allowed to rest on C bandraster pro les with the width size from 100mm to 200mm and length up to 3000mm, providing straight and aesthe c look as well as sharp levelling the panels with the grid pro les. All panels are demountable manually without any special tool so that the system enables fast and easy access to the ceiling void.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD
Panel type0.5 ~ 1.0 mm aluminium or galvanised steel
Panel sizeWidth up to 1250 mm. Length up to 3000 mm. Height 30-50 mm
Grid system50 – 75 – 100 – 125 – 150mm
PerforationFull perfore, 5 cm – 10 cm bordered, non-perforated
Ø0.7 mm. / Ø1.5 mm. / Ø1.8 mm. / Ø2.5 mm.
Acoustic feltLocal, soundtex, royalin, lantor acoustic and non-flammable felt options
Certi cationsTSE (EN 13964), CE

1.2.      OPEN – CELL CEILINGS

1.2.a.      SEQUARE OPEN – CELL                                            1.2.b.     TRIANGLE OPEN – CELL                             

Tetra B        

Tetra S             

   Triangle open – cell

 

Tetral Inverse

 Monoblade

                    1.2.c.       LINEER OPEN – CELL

  Tetral Line                    Deltaceir Line

               

 Reflex

1.3.       EXPANDED METAL – MESHES CEILINGS

1.4.       LINEER CEILING – HORIZONTAL

Panel C                                    Panel F

 Panel B – Multipanel            Panel 85

 

1.5.       LINEER CEILING – VERTICAL

Vectorial ceilings V100 – V200                Spiked baffle                                  Extruded aluminium baffle                Extruzyon tube

2.      GYPSUM BOARDS SYSTEM CEILING

2.1.            VINYL LAMINATED PERFORATED GYPSUM TILE

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

Gypsum board

Panel size

min.300mm – max.1200mm / min. 300mm – max 2400mm

Panel thickness

8 – 9.5 – 12.5mm

Front surface

Pvc vinyl coated or without PVC, dyed

Back surface

Black and White interlining fabric coated

Side surface

Without sideband

Panel weight

Varies according to product thickness

Fire class

A2

  1. T15/24 Main carrier 3600 mm              5. Z or L angle 300 mm
  2. T15/24 Crossbar 1200 mm                   6. Double spring
  3. T15/24 Secondary carrier 600 mm      7. Steel dowel
  4. T15/24 Secondary carrier 300 mm      8. Suspension tie

Slotted                                       Circle 4mm     

Circle 10mm                            Square hole 10x10mm

 Square hole 4×4                      Circle 6mm

Big and small hole                     Irregular hole            

2.2.            VINYL LAMINATED GYPSUM TILE

 

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

Gypsum board

Panel size

min.300mm – max.1200mm / min. 300mm – max 2400mm

Panel thickness

7- 8 – 9.5 – 12.5mm

Front surface

Pvc vinyl coated

Back surface

Aluminium foil coated

Edge detail

Can be produced with edge bands on request

Panel weight

Varies according to product thickness

Fire class

A2

     Vinyl 154                 Vinyl 259               Vinyl  865 Akasya        Vinyl 874 Beech

 

 Vinyl  886 Cherry     Vinyl  605                  Vinyl  127 – G

       Vinyl  238            Vinyl  238 – G           Vinyl  238 – S

   

2.3.         UV PAINTED GYPSUM TILE

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

Gypsum board

Panel size

min.300mm – max.1200mm / min. 300mm – max 2400mm

Panel thickness

7- 8 – 9.5 – 12.5mm

Front surface

UV painted

Back surface

Aluminium foil

Panel weight

Varies according to product thickness

Fire class

A2

3. ROCKWOOL CEILING

As stone wool is non hygroscopic, the tiles withstand up to 100% relative humidity and maintain dimensional stability. The stone wool does not contain organic nutrients and so is not attacked by rot, fungi or bacteria. Thanks to Rockfon’s excellent humidity resistance and extremely low susceptibility to microorganisms, the brown stains those occurred because of bacteria pukes are never seen on Rockfon surface.

3.1.  MODULAR CEILINGS

 

3.2. BAFFLES AND ISLANDS

 

 3.3. COLOR ALL SERIES

 3.4. ACOUSTIC

4. PVC PANEL SYSTEMS

4.1.            30 x 30 PVC PANELS

It enriches the space with the aesthetics it adds to suspended ceilings with many colour and pattern options. It hides ventilation ducts, plumbing and electrical equipment. It does not allow the growth of bacteria and fungi and provides hygiene. It is the most suitable material for hospitals, food industry and laboratories.B1 Class; Flame retardant. Thanks to its very low flammability, it does not ignite easily, does not burn on its own and extinguishes immediately as a result of removing the flame source.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

PVC

Panel size

30 x 30

Plate thickness

0,7 mm

Plate weight

Kg / 1m² 4,48 + –

Fire class

B1

 

4.2.            PORTRAIT PVC PANELS

It is not affected by water and humidity with its water-repellent structure. It is the ideal solution for the ceilings of humid environments such as kitchens, wet process areas, indoor swimming pools. It does not burden the ceiling and is easy to install. Fully integrated with galvanised or aluminium T-24 and T-15 carrier systems. It does not allow the growth of bacteria and fungi, provides hygiene. It is the most suitable material for hospital, food industry and laboratory. Class B1; Flame retardant. Thanks to its very low flammability, it does not ignite easily, does not burn on its own and extinguishes immediately as a result of removing the flame source.

TECHNICAL SPECIFICATIONS AND THE TSE STANDARD

Panel type

PVC

Panel size

59,5 x 59,5

Plate thickness

0,8 mm

Plate weight

Kg / m² 2,35 + –

Fire class

B1

Çamlıca Mah.Anadolu Bulvarı Timko Sokak No: 20 Blok : F10 Yenimahalle / ANKARA
Mon - Sat: 8:00-18:00
Help?